Golf Car Batteries
27+ Years of Experience | Licensed and Insured | Family-Owned Business
27+ Years of Experience
Licensed and Insured
Family-Owned Business
Choose the Right Battery for Your Golf Cart
At Centennial Batteries, we have the power to keep your golf car moving with a full selection of deep cycle 6-volt, 8-volt and 12-volt battery models to meet your needs.
Call Redding Golf Car for more information.
Centennial Golf Car - 6,8 & 12 Volt
BCI GROUP SIZE | CENTENNIAL PART NO. | AH @ 20HR | AH @ 5HR | RC minutes @ 25amps | RC minutes @ 75amps | VOLTAGE | LENGTH | WIDTH | HEIGHT |
---|---|---|---|---|---|---|---|---|---|
GC2 | GC2200P | 216 | 172 | 445 | 114 | 6 | 10 1/4 | 7 1/8 | 11 1/4 |
GC2 | GC2350 | 235 | 195 | 475 | 125 | 6 | 10 1/4 | 7 1/8 | 11 1/4 |
GC2H | C-145 | 245 | 210 | 530 | 145 | 6 | 10 1/4 | 7 1/8 | 11 1/4 |
GC8 | GC8VP | 165 | 145 | 299 | 100 | 8 | 10 1/4 | 7 1/8 | 11 1/4 |
GC12 | GC1275P | 150 | 125 | 290 | 70 | 12 | 12 7/8 | 7 1/8 | 10 11/16 |
CCA - Cold Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 0 degrees farenheit at a voltage above 1.2 v/cell.
CA - Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell.
MCA - Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell.
RC - Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80 degrees farenheit and maintain a voltage above 1.75 v/cell.
AH - Ampere Hour Capacity - A unit measurement for electron flow or current through an electrical circuit for a certain period of time. The 20 hour rate is a BCI sanctioned rating expressing ampere hours required to achieve an end voltage of 1.75 v/cell at 90 degrees farenheit , and represents the batteries maximum capacity. The 5 hour rate is based on IEC (International Electrotechnical Commission) temperature standard of 30 degrees celsius (86 degrees farenheit ).
The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development. We reserve the right to change design, specifications, or pricing at anytime without notice and without incurring obligation.
6V T-105 Deep-Cycled Flooded
BCI GROUP SIZE | TYPE | Capacity Minutes | Capacity Amp-Hours | Energy (kWh) | Terminal Type | Dimension inches (mm) | Weight lbs. (kg) |
---|---|---|---|---|---|---|---|
GC2 | T-105 | @25 Amps 447 | 5-Hr Rate 185 | 150 | 1,2,3,4 | Length 10.30(262) | 62 (28) |
@75 Amps 115 | 10-Hr Rate 207 | Width 7.11(181) | |||||
20-Hr Rate 225 | Height 11.07(281) | ||||||
100-Hr Rate 2250 |
Voltage: 8-Volt Deep Cycle – Golf, Multi-purpose
Data: 20 Hour Rate: 170
Minutes of Discharge @ 75 Amps: 90
Minutes of Discharge @ 25 Amps: 337
Length: 10 1/4” (260mm)
Width: 7 1/8” (181mm)
Height: 11 1/4” (286mm)
Additional Information:
U.S Battery’s Flooded Lead Acid batteries are engineered and proven to provide the fastest cycle-up to full rated capacity, and have the highest total energy delivered over the life of the battery.
Building the best Flooded Lead Acid Battery on the market comes from a better cell design, hand-made construction, and attention to details.
Share On: